effects of compensation and benefit package on employees’ turnover and job satisfaction at Equity Bank, Nairobi , Kenya- hrm research project

Institution Kisii National Polytechnic
Course Human resource manag...
Year 3rd Year
Semester Unknown
Posted By MAKORI KERECHA
File Type docx
Pages
File Size 104.6 KB
Views 1256
Downloads 0
Price: Buy Now whatsapp Buy via whatsapp
  • whatsapp
  • facebook
  • twitter

Description

The purpose of this research was to assess the effects of compensation and benefit package on employees’ turnover and job satisfaction at Equity Bank, Nairobi , Kenya . To achieve this objective, both qualitative and quantitative data were collected from 91 employees who were selected using simple random sampling technique. Questionnaires and interviews were used to collect data from employees of Equity Bank working in the Head office. Once the data were collected, they were coded, edited, and analyzed. The major findings indicated that in Equity Bank there are different compensation packages such as salary, transport allowance, hardship allowance, telephone allowance, etc. The bank is good at providing annual leave. However, it is weak in the following benefit packages: providing food and beverage to its employee, establishing employee clubs and implementing weak talent management practices, this means the existence of ineffective, redundant and not carrier related training practices. On the other hand, there are different other major problems. Employees do not participate in compensation and benefit decision-making process. Additionally, poor work environment and work culture prevail at the bank. These all may decrease job satisfaction and increase staff turnover. It can then be concluded that most of the respondents were not satisfied with the existing compensation and benefit packages because of the aforementioned reasons. Finally, the all findings lead to the thought that Equity Bank S.C. has to review its current compensation and benefit package in order to retain employees for long period of time (decrease turnover) and increase their job satisfaction.
Below is the document preview.

No preview available
DESIGN OF REINFORCED RETAINING WALL PROJECT REPORT
To achieve the objective of this study as stated earlier, the visit companies and offices in order to get the data which will help me to get better result and produce a good report of my research project. This work will be arranged in this way, Step1; to deal with descriptive study and documenting which show how kabaya terrain is look like and carrying survey and site investigation. Step2; to produce descriptive study showing drawing based on data will be obtaining Step2; to assess cost estimation by using appropriate concept
876 Views 0 Downloads 864.4 KB
STRUCTURAL AND ARCHITECTURAL DESIGN OF FOUR STOREY MULTI-SHOPPING COMMERCIAL BLOCK PROJECT REPORT
This project entitled “Structural design of four-story multi-shopping commercial block in Kisii Town”. The objective the research was to conduct a technical detail and study on the implementation of Structure design of proposed four story commercial building in Kisii Town in order to solve the problems of our country to fit in vision of land use. Therefore, conducting this research project could be a sustainable solution to the above-mentioned problems. During this research, the analysis of structural elements was made by combining manual analysis, ArchiCAD 18 & Atlantis software for providing architectural plans, arcGIS software for creating and using maps, compiling geographic data, analyzing mapped information, dynamic cone penetration test for determining allowable bearing capacity of the soil, PROKON software for analyzing and designing of structures. The architectural drawings, analysis and the design of all elements of structure, cross sections and reinforcements were calculated. The study revealed that building dimensions are (21.30m*25.60m) and the minimum requirements steel bar in slab at the top four steel bars of ten diameters (4Ø10mm/m), bottom three steel bars of eight diameters (3Ø8mm/m). Beam at top four steel bar of twenty five diameters (4Ø25mm), bottom (4Ø20mm). For the column ground floor (8Ø25mm), first floor (8Ø20mm), second floor (8Ø14mm) and last (4Ø12mm), stairs (4 Ø 12), foundation (5Ø16mm)
891 Views 0 Downloads 4.11 MB
STRUCTURAL DESIGN OF MORDERN THREE STOREY HOUSE WITH ROOFTOP TERRACE PROJECT REPORT
This work explores the complexities and challenges of designing a three-storey modern house in Kisii Town, Kisii County. In response to rapid urbanization and the essential role of housing in Kisii County(World Bank, 2018;UN-Habitat 2018), there is an increasing demand for modern, sustainable, and community-oriented residential spaces. This study was conducted to help meet the need for modern housing in Kisii County, as the County faces many challenges in providing adequate and sustainable homes. The project explains the design and modelling of a G+2, three-storey modern house using Autodesk Robot Structural Analysis Professional 2024(Autodesk 2023), as it provides a clear vision through design, construction, and documentation. With the advancement of technology, the use of software to solve numerous problems in every technical discipline problems that formerly took a long time has become quite common. As a result, the use of software technology in civil engineering to analyze, design, and predict the behavior of structures before their lifespan has increased dramatically over the last decade(Kasthurirangan, 2021). The research focused on designing a modern house with a rooftop terrace, taking into account practical use, visual appeal, safety, and economic viability. Archi CAD 28(Graphisoft, 2023) and Lumion 10(Act-3D, 2020) software were used for producing the architectural design, while Robot Structural Professional was employed for structural design and analysis, following the British Code as the design standar
832 Views 0 Downloads 4.84 MB
STRUCTURAL AND ARCHITECTURAL DESIGN OF TWO COMMERCIAL BUILDING BLOCK PROJECT REPORT
This is a project for construction of two storey commercial building block. This project work “structural design of G+2 commercial building at Nyamache Sub County_ Kisii County sector is a part of fulfillment of advanced diploma as awarded of Kisii National polytechnic (KNP). It contains with conception, structural design which provides proper communication to all of users, this project gives more information about the design and analysis of commercial building. The final project report contains five chapters that are: General Introduction, Literature review, research methodology, system design, analysis and implementation and then Conclusion and Recommendation. This project report also has been compiled referred to books of different authors and by using equation provided in codes of practice like; British standard used in design of the commercial building. The analysis of each structure members starts with evaluation of all loads that are expected to be carried by structure including self-weight. The structure design of this project detail, beam, slab, stair, column, and foundation by BS8110. Based on result, the detailed plans of this.
859 Views 0 Downloads 2.37 MB